<PlanDefinition xmlns="http://hl7.org/fhir">
<id value="VentilatedARDSPatientsInterventionPlan"/>
<meta>
<profile
value="https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/recommendation-plan"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: PlanDefinition VentilatedARDSPatientsInterventionPlan</b></p><a name="VentilatedARDSPatientsInterventionPlan"> </a><a name="hcVentilatedARDSPatientsInterventionPlan"> </a><a name="VentilatedARDSPatientsInterventionPlan-en-US"> </a><p><b>url</b>: <a href="PlanDefinition-VentilatedARDSPatientsInterventionPlan.html">PlanDefinition Ventilation parameters for patients with ARDS</a></p><p><b>version</b>: 7.0</p><p><b>name</b>: Ventilation_Plan_ARDS</p><p><b>title</b>: Ventilation parameters for patients with ARDS</p><p><b>type</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/plan-definition-type eca-rule}">ECA Rule</span></p><p><b>status</b>: Active</p><p><b>experimental</b>: true</p><p><b>subject</b>: <a href="EvidenceVariable-PopulationVentilatedARDSPatients.html">Population: Ventilated patients with ARDS</a></p><p><b>date</b>: 2022-02</p><p><b>publisher</b>: NUM CODEX+ CELIDA</p><p><b>description</b>: </p><div><p>We recommend ventilating patients with ARDS with a VT ≤ 6 ml/kg standard body weight (bw). (Table 1, Appendix)</p>
</div><blockquote><p><b>goal</b></p><blockquote><p><b>id</b></p>tidal-volume-ARDS-goal</blockquote><p><b>category</b>: <span title="Codes:{http://snomed.info/sct 385857005}">Ventilator care and adjustment (regime/therapy)</span></p><p><b>description</b>: <span title="Codes:">Tidal volume ≤ 6 ml/kg standard body weight</span></p><h3>Targets</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Measure</b></td><td><b>Detail[x]</b></td></tr><tr><td style="display: none">*</td><td><span title="Codes:{https://www.netzwerk-universitaetsmedizin.de/fhir/codex-celida/CodeSystem/codex-celida tvpibw}">Tidal volume / ideal body weight (ARDSnet)</span></td><td>?-6</td></tr></table></blockquote><h3>Actions</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Code</b></td><td><b>GoalId</b></td></tr><tr><td style="display: none">*</td><td><span title="Codes:{http://snomed.info/sct 410210009}">Ventilator care management (procedure)</span></td><td>tidal-volume-ARDS-goal</td></tr></table></div>
</text>
<extension
url="http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-knowledgeCapability">
<valueCode value="computable"/>
</extension>
<extension
url="http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-knowledgeRepresentationLevel">
<valueCode value="structured"/>
</extension>
<extension url="http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-partOf">
<valueCanonical
value="https://www.netzwerk-universitaetsmedizin.de/fhir/codex-celida/guideline/sepsis/recommendation/ventilation-plan-ards-tidal-volume"/>
</extension>
<extension
url="https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/ext-action-combination-method">
<extension url="method">
<valueCodeableConcept>
<coding>
<system
value="https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-action-combination-method"/>
<code value="all"/>
</coding>
</valueCodeableConcept>
</extension>
</extension>
<url
value="https://www.netzwerk-universitaetsmedizin.de/fhir/codex-celida/guideline/sepsis/intervention-plan/ventilation-ARDS-plan"/>
<version value="7.0"/>
<name value="Ventilation_Plan_ARDS"/>
<title value="Ventilation parameters for patients with ARDS"/>
<type>
<coding>
<system
value="http://terminology.hl7.org/CodeSystem/plan-definition-type"/>
<code value="eca-rule"/>
</coding>
</type>
<status value="active"/>
<experimental value="true"/>
<subjectCanonical
value="https://www.netzwerk-universitaetsmedizin.de/fhir/codex-celida/guideline/sepsis/population/ventilated-patients-with-ards"/>
<date value="2022-02"/>
<publisher value="NUM CODEX+ CELIDA"/>
<description
value="We recommend ventilating patients with ARDS with a VT ≤ 6 ml/kg standard body weight (bw). (Table 1, Appendix)"/>
<goal id="tidal-volume-ARDS-goal">
<category>
<coding>
<system value="http://snomed.info/sct"/>
<code value="385857005"/>
<display value="Ventilator care and adjustment (regime/therapy)"/>
</coding>
</category>
<description>
<text value="Tidal volume ≤ 6 ml/kg standard body weight"/>
</description>
<target>
<measure>
<coding>
<system
value="https://www.netzwerk-universitaetsmedizin.de/fhir/codex-celida/CodeSystem/codex-celida"/>
<code value="tvpibw"/>
<display value="Tidal volume / ideal body weight (ARDSnet)"/>
</coding>
</measure>
<detailRange>
<high>
<value value="6"/>
<unit value="ml/kg"/>
<system value="http://unitsofmeasure.org"/>
<code value="ml/kg"/>
</high>
</detailRange>
</target>
</goal>
<action>
<code>
<coding>
<system value="http://snomed.info/sct"/>
<code value="410210009"/>
<display value="Ventilator care management (procedure)"/>
</coding>
</code>
<goalId value="tidal-volume-ARDS-goal"/>
</action>