"resourceType" : "PlanDefinition",
"id" : "VentilatedARDSPatientsInterventionPlan",
"meta" : {
"profile" : [
🔗 "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/recommendation-plan"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: PlanDefinition VentilatedARDSPatientsInterventionPlan</b></p><a name=\"VentilatedARDSPatientsInterventionPlan\"> </a><a name=\"hcVentilatedARDSPatientsInterventionPlan\"> </a><a name=\"VentilatedARDSPatientsInterventionPlan-en-US\"> </a><p><b>url</b>: <a href=\"PlanDefinition-VentilatedARDSPatientsInterventionPlan.html\">PlanDefinition Ventilation parameters for patients with ARDS</a></p><p><b>version</b>: 7.0</p><p><b>name</b>: Ventilation_Plan_ARDS</p><p><b>title</b>: Ventilation parameters for patients with ARDS</p><p><b>type</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/plan-definition-type eca-rule}\">ECA Rule</span></p><p><b>status</b>: Active</p><p><b>experimental</b>: true</p><p><b>subject</b>: <a href=\"EvidenceVariable-PopulationVentilatedARDSPatients.html\">Population: Ventilated patients with ARDS</a></p><p><b>date</b>: 2022-02</p><p><b>publisher</b>: NUM CODEX+ CELIDA</p><p><b>description</b>: </p><div><p>We recommend ventilating patients with ARDS with a VT ≤ 6 ml/kg standard body weight (bw). (Table 1, Appendix)</p>\n</div><blockquote><p><b>goal</b></p><blockquote><p><b>id</b></p>tidal-volume-ARDS-goal</blockquote><p><b>category</b>: <span title=\"Codes:{http://snomed.info/sct 385857005}\">Ventilator care and adjustment (regime/therapy)</span></p><p><b>description</b>: <span title=\"Codes:\">Tidal volume ≤ 6 ml/kg standard body weight</span></p><h3>Targets</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Measure</b></td><td><b>Detail[x]</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{https://www.netzwerk-universitaetsmedizin.de/fhir/codex-celida/CodeSystem/codex-celida tvpibw}\">Tidal volume / ideal body weight (ARDSnet)</span></td><td>?-6</td></tr></table></blockquote><h3>Actions</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Code</b></td><td><b>GoalId</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{http://snomed.info/sct 410210009}\">Ventilator care management (procedure)</span></td><td>tidal-volume-ARDS-goal</td></tr></table></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-knowledgeCapability",
"valueCode" : "computable"
},
{
"url" : "http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-knowledgeRepresentationLevel",
"valueCode" : "structured"
},
{
"url" : "http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-partOf",
"valueCanonical" : "https://www.netzwerk-universitaetsmedizin.de/fhir/codex-celida/guideline/sepsis/recommendation/ventilation-plan-ards-tidal-volume"
},
{
"extension" : [
{
"url" : "method",
"valueCodeableConcept" : {
"coding" : [
{
"system" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-action-combination-method",
"code" : "all"
}
]
}
}
],
"url" : "https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/ext-action-combination-method"
}
],
"url" : "https://www.netzwerk-universitaetsmedizin.de/fhir/codex-celida/guideline/sepsis/intervention-plan/ventilation-ARDS-plan",
"version" : "7.0",
"name" : "Ventilation_Plan_ARDS",
"title" : "Ventilation parameters for patients with ARDS",
"type" : {
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/plan-definition-type",
"code" : "eca-rule"
}
]
},
"status" : "active",
"experimental" : true,
"subjectCanonical" : "https://www.netzwerk-universitaetsmedizin.de/fhir/codex-celida/guideline/sepsis/population/ventilated-patients-with-ards",
"date" : "2022-02",
"publisher" : "NUM CODEX+ CELIDA",
"description" : "We recommend ventilating patients with ARDS with a VT ≤ 6 ml/kg standard body weight (bw). (Table 1, Appendix)",
"goal" : [
{
"id" : "tidal-volume-ARDS-goal",
"category" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "385857005",
"display" : "Ventilator care and adjustment (regime/therapy)"
}
]
},
"description" : {
"text" : "Tidal volume ≤ 6 ml/kg standard body weight"
},
"target" : [
{
"measure" : {
"coding" : [
{
"system" : "https://www.netzwerk-universitaetsmedizin.de/fhir/codex-celida/CodeSystem/codex-celida",
"code" : "tvpibw",
"display" : "Tidal volume / ideal body weight (ARDSnet)"
}
]
},
"detailRange" : {
"high" : {
"value" : 6,
"unit" : "ml/kg",
"system" : "http://unitsofmeasure.org",
"code" : "ml/kg"
}
}
}
]
}
],
"action" : [
{
"code" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "410210009",
"display" : "Ventilator care management (procedure)"
}
]
},
"goalId" : [
"tidal-volume-ARDS-goal"
]
}
]
}